29.10 Density-fitted LMP2 (DF-LMP2)
and coupled cluster (DF-LCCSD(T0))
Density-fitting LMP2 and LCCSD calculations can be performed by adding the prefix DF-
to the command name.
The input is as follows:
DF-LMP2,[options]
DF-LCCSD(T),[options]
Options for density fitting can be mixed with any options for LOCAL. Options for
density fitting can also be given on a DFIT directive (see section 11).
The most important options for density fitting in local methods are
- BASIS_MP2=string
- Fitting basis set used in LMP2 and in LCCSD for integrals
with up to 2 external orbitals. If a correlation consistent basis set is used (e.g. cc-pVTZ)
the corresponding fitting basis for MP2 us used by default (cc-pVTZ/MP2FIT). Otherwise the
fitting basis set must be defined in a preceding basis block (see section 13).
- BASIS_CCSD=string
- Fitting basis set used in LCCSD for integrals
over 3- and 4-external orbitals. The default is BASIS_MP2 and this is usually sufficient.
However, the accurate approximation
of 4-external integrals in LCCSD requires larger fitting basis sets than LMP2. Therefore, in order to minimize
fitting errors, it is recommended to use the next larger fitting basis, e.g., BASIS_CCSD=VQZ
for orbital basis VTZ.
- LOCFIT=value:
- If LOCFIT=1 local fitting is enabled. This is necessary to
achieve linear scaling in DF-LMP2 (see Refs. [11-14]). The errors introduced by local fitting are
usually very small, but there are some exceptions.
For instance, LOCFIT=1 must not be used in counterpoise calculations, see section 29.9.8)
Note that for small molecules LOCFIT=1 can be more expensive than
LOCFIT=0.
For further details and options for density fitting see section 11.