Next: 31 THE FULL CI
Up: 30 EXPLICITLY CORRELATED METHODS
Previous: 30.12 DF-LMP2-F12 calculations with
30.13 Variables set by the F12 programs
The following variables are set by the F12 programs:
- ENERGR
- Reference energy. This includes the perturbative CABS singles
correction if computed.
- ENERGY
- Total energy of the requested method (including the F12 and singles corrections).
ENERGY(1) and ENERGY(2) hold the F12A and F12B values, respectively (if both are computed).
- ENERGC
- Total CCSD-F12 energies in ccsd-f12 or uccsd-f12 calculations.
ENERGC(1) and ENERGC(2) hold the F12A and F12B values, respectively (if both are computed).
The difference of ENERGY and ENERGC is the triples energy contribution.
- ENERGT
- Triples energy contribution. This is a vector. The corresponding methods are stored in
METHODT (strings).
- EMP2
- Total MP2 energy (excluding F12 correction, but including the singles correction).
- EMP2_SCS
- Total SCS-MP2 energy (excluding F12 correction, but including the singles correction).
- EMP2_SING
- Singlet MP2 correlation energy (excluding F12 correction).
- EMP2_TRIP
- Triplet MP2 correlation energy (excluding F12 correction).
- EMP2_STRONG
- Strong pair contribution to the LMP2 correlation energy (where applicable).
- EMP2_CLOSE
- Close pair contribution to the LMP2 correlation energy (where applicable).
- EMP2_WEAK
- Weak pair contribution to the LMP2 correlation energy (where applicable).
- EMP2_DIST
- Distant pair F12 contribution to the LMP2-F12 correlation energy (where applicable).
- EF12
- F12 contribution to the MP2-F12 correlation energy for the requested ansatz.
- EF12S
- F12 contribution to the MP2-F12 correlation energy using EBC approximation for the requested ansatz.
- EF12D
- F12 contribution to the MP2-F12 correlation energy using EBC approximation and diagonal (DX) approximation for the requested ansatz.
- EF12_SING
- Singlet F12 contribution to the MP2-F12 correlation energy for the requested ansatz.
- EF12_TRIP
- Triplet F12 contribution to the MP2-F12 correlation energy for the requested ansatz.
- EF12_STRONG
- Strong pair F12 contribution to the LMP2-F12 correlation energy (where applicable).
- EF12_CLOSE
- Close pair F12 contribution to the LMP2-F12 correlation energy (where applicable).
- EF12_WEAK
- Weak pair F12 contribution to the LMP2-F12 correlation energy (where applicable).
- EF12_DIST
- Distant pair F12 contribution to the LMP2-F12 correlation energy (where applicable).
- EF12_SCS
- F12 contribution to the MP2-F12 correlation energy for the requested ansatz.
- EF12_SINGLES
- Total CABS singles contribution (in closed-shell case equal to EF12_RHFRELAX).
- EF12_RHFRELAX
- CABS singles correction of the reference energy (only the spin-free contribution is used).
- ANSATZ
- The requested ansatz (string variable)
Variables corresponding to EF12_* exist also for EF12S_* and EF12D_*.
In case of doubt or problems, try in a test calculation
SHOW,ENERG*,EMP2*,EF12*
This should show all relevant variables that exist. Note that system variables are internally
stored with an underscore as a prefix, and this may be shown by the SHOW command.
The variables can be accessed with or without underscore (but if the user defines a
variable with the same name then the underscore is needed to access the system variable
and not the user variable).
Next: 31 THE FULL CI
Up: 30 EXPLICITLY CORRELATED METHODS
Previous: 30.12 DF-LMP2-F12 calculations with
molpro@molpro.net
Sep 24, 2008