Next: 6.18.2 Procedures for geometry Up: 6.18 Default procedures Previous: 6.18 Default procedures

6.18.1 Procedures for energy calculations

The wavefunction symmetry and spin can be modified using the variables SYMMETRY and SPIN, respectively. The number of electrons can be modified using the variable NELEC. SCF calculations are only done if no orbitals are available or if the symmetry or spin changed since the last SCF optimization. In CASPT and MRCI calculations the CASSCF is only done if the last optimized orbitals are not of MCSCF type.
runscf
Performs SCF calculation.
rundft
Performs DFT calculation. The functional can be specified using either the FUNCTIONAL or DFTNAME variable (default=B3LYP).
runmp2
Performs SCF and MP2 calculations.
runmp3
Performs SCF, MP2 and MP3 calculations.
runmp4
Performs SCF and MP2-MP4 calculations.
runmp4sdq
Same as runmp4, but without triples.
runccsd
Performs SCF and CCSD calculations. Uses RCCSD in open-shell cases.
runccsdt
Performs SCF and CCSD(T) calculations. Uses RCCSD(T) in open-shell cases.
runuccsd
Performs SCF and CCSD calculations. Uses UCCSD in open-shell cases.
runuccsdt
Performs SCF and CCSD(T) calculations. Uses UCCSD(T) in open-shell cases.
runbccd
Performs SCF and BCCD calculations (closed-shell only).
runbccdt
Performs SCF and BCCD(T) calculations (closed-shell only).
runqcisd
Performs SCF and QCISD calculations (closed-shell only).
runqcisdt
Performs SCF and QCISD(T) calculations (closed-shell only).
runcas
Performs SCF and CASSCF calculation. The wavefunctions for state averaged CASSCF calculations can be defined using the variables SYMMETRY, SPIN, STATE, WEIGHT, and NELEC.
caspt2
Performs SCF, CASSCF, and CASPT2 calculations. In case of state-averaged CASSCF reference functions (see runcas) the CASPT2 is performed for each state separately.
caspt3
As CASPT2, but also computes third-order energy.
runcaspt2
Same as caspt2.
runcaspt3
Same as caspt3.
runmrci
Performs SCF, CASSCF, and MRCI calculations. In case of state-averaged CASSCF reference functions (see runcas) the MRCI is performed for each state symmetry separately. Several states in the same symmetry are treated simultaneously. Transition moments are automatically computed between all states. However, these are not printed in the summary at the end of the output and must be extracted from the output or punch file.
runacpf
Performs SCF, CASSCF, and MR-ACPF calculations. At present, multiple-state MR-ACPF calculations are not possible.


Next: 6.18.2 Procedures for geometry Up: 6.18 Default procedures Previous: 6.18 Default procedures